Your Company
Professional Home Inspection

INSPECTION REPORT

8-28-2026
Inspector
Inspector Name
Client
Sample Client
123 Sample St, Springfield

INSPECTION AGREEMENT SUMMARY: Your Company & Sample Client

This document constitutes a legally binding contract and details the terms of the home inspection carried out by Your Company. Clients are advised to review this agreement carefully.  The inspection fee is based on the time invested in conducting the inspection and preparing the report, independent of repair costs, and is due regardless of the property purchase decision. No responsibility is assumed for costs related to identified or future defects. The inspector disclaims knowledge of any items not explicitly mentioned in this report. The services of relevant professionals (electricians, plumbers, HVAC technicians, roofers, structural engineers) may be necessary to address issues noted.

DESCRIPTION OF INSPECTION FINDINGS:

  • Inspected: Area or component was thoroughly examined, and no issues were found at the time of inspection.
  • Not Inspected: Area or supporting component was not inspected and may require further evaluation.
  • Not Present: Area or component does not exist on the property or could not be visually located.
  • Moisture Evidence Present: Visible signs of moisture or water-related issues were observed; further evaluation is recommended.

INSPECTION DETAILS:

  • Visual Only: This inspection is a non-invasive, visual examination of the readily accessible areas of the property to identify material defects in specified systems and components.  
  • Scope: A visual review of accessible areas to identify defects in specified systems and components, modifiable upon client-inspector agreement.
  • Limitations: The inspection is not exhaustive, excluding hidden, concealed, or inaccessible defects. Personal belongings and furniture are not moved during the inspection.
  • Equipment Testing: Involves testing responses to normal controls without disassembly, except for easily removable service panels.
  • Observation-Based: Findings are specific to the inspection date and do not predict future conditions. Not all defects may be identified.
  • Material Defects: Identified issues significantly affecting property value or posing unreasonable risks.

EXCLUSIONS AND LIMITATIONS:

  • Limited solely to the paid inspection fee. Excludes liability for repair costs, property damage, or injury. The report is intended only for the client named above and is not a guarantee, warranty, or insurance policy.

CLIENT ACKNOWLEDGMENT:

  • Non-Compliance and Hidden Defects: Areas not evaluated for safety code compliance may contain hidden defects that cannot be identified during a visual inspection.
  • Special Loan Types: This inspection does not assess or comment on FHA standards, which are subject to change.
  • Environmental and Specialized Inspections: This inspection does not include testing for radon, lead-based paint, asbestos, mold, or other potentially hazardous substances. Private systems and pest inspections are also excluded.
  • Liability: Liability is limited solely to the amount of the paid inspection fee. The inspection report does not cover repair costs, property damage, or injury. It is intended exclusively for the client and does not serve as a guarantee, warranty, or insurance policy.
  • Modern Standards: Highlights safety issues but does not inspect for code compliance. Observations on mixed materials and incomplete areas are included. Manufacturer recalls are not part of the inspection. 

Table of Contents

GENERAL SUMMARY

Inspector Name

Customer: Sample Client
Address: 123 Sample St, Springfield

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.

1. Roof - Summary

1.1

Roof Covering Materials

Inspected
Summary photo 1 1.1-1
COMMENT:

Shingles appeared to be slightly raised or were not laying flat, similar to nearby shingles. Continued monitoring during routine maintenance is recommended to ensure the long-term integrity of the roofing system. May indicate hidden failure below the roof covering. Keep budget for repairs when shingles are replaced.

Summary photo 1 1.1-3
COMMENT:

Moderate granule loss was observed on the roof shingles, which is consistent with an aging roof. Based on an age of 1999, the roof would be at or near its end of life span. The client should confirm the exact age with the seller and budget for eventual replacement.

2. Exterior - Summary

2.7

Stairs, Steps, Stoops, Stairways & Ramps

Inspected
Summary photo 1 2.7-1
COMMENT:

Space between railing measured 4 inches or more, which is common in homes of this age. However may be a requirement for some loan types.

Summary photo 1 2.7-2
COMMENT:

Moderate, however general wear and tear at concrete with exposed rebar, was noted at the front entry stairs. The material was not loose at the time of inspection however appeared to have a crumbling effect. A gap or exposed area was also present. Maintenance to increase life span.

2.10

Vegetation, Surface Drainage, Retaining Walls & Grading

Inspected
Summary photo 1 2.10-2
COMMENT:

Visual access to the exterior wall was limited by vegetation; regular maintenance is recommended. Comments on visual ares only. Trimming is needed to see the exterior wall. Limited visibility.

3. Structural Components - Summary

3.5

Floor Structure

Inspected
PROFESSIONAL NEEDED
Summary photo 1 3.5-1
COMMENT:

The floor in the upstairs bathroom near the toilet was observed to be not level. Localized staining was noted on the vinyl; further evaluation is recommended. The nearby wall was bowed out. Further evaluation in this area is strongly recommended. The nearby vinyl near toilet had a stain. Dry at time.

Summary photo 1 3.5-3
COMMENT:

Stains were observed on the floor structure above the upstairs bathroom. This area was dry at the time of inspection; monitor for changes.

4. Heating & Cooling - Summary

4.1

Heating System

Inspected
WARNING
Summary photo 1 4.1-1
COMMENT:

Potential asbestos wrap was observed on the heating system. Testing or appropriate covering is recommended.

5. Plumbing - Summary

5.3

Water Heater - Venting, TPR Valves & Seismic Bracing

Inspected
SAFETY ISSUE
Summary photo 1 5.3-1
COMMENT:

It is recommended to reduce the water temperature to 120 Fahrenheit. 138 degrees at time, may increase chance of burns.

5.4

Interior Water Supply, Fixtures & Faucets

Inspected
Summary photo 1 5.4-1
COMMENT:

The water source to the exterior spigot was off at the time of inspection, preventing full evaluation of its condition and operation. This condition limits the ability to determine if leaks or other issues are present. Further evaluation is recommended once the water supply is active.

Summary photo 1 5.4-2
COMMENT:

A leak was observed at the water spigot when the water source was turned on. Further evaluation and repair by a qualified plumber are recommended.

5.6

Sinks, Tubs & Showers (Functional Drainage)

Inspected
Summary photo 1 5.6-1
COMMENT:

No shut-off valves were observed for the sink at the time of inspection. Without these valves, it is not possible to isolate water flow to the fixture for maintenance or in case of a leak. Recommend installation of shut-off valves by a qualified plumber.

Summary photo 1 5.6-2
COMMENT:

The sink drain in the upstairs bathroom was observed to be slightly slow. Monitor this condition over time. Strongly recommend a sewer scope.

5.7

Drain, Waste & Vent System

Not Inspected
Summary photo 1 5.7-2
COMMENT:

An open or exposed drain pipe should be sealed, at washing machine. Visible corrosion or scaling was noted on the base of the washing machine; keep budget in mind for replacement.

6. Electrical - Summary

6.2

Meter and Service Wiring

Inspected
Summary photo 1 6.2-1
COMMENT:

A hanging or loose wire was observed, and further evaluation and repair by a qualified electrician is recommended.

6.3

Main Panel and Breakers

Deficient
DANGERPROFESSIONAL NEEDED
Summary photo 1 6.3-1
COMMENT:

A Federal Noark electrical panel is an older distribution box made by the company that later became Federal Pacific Electric (FPE), and it poses significant safety and fire risks due to known failure-to-trip defects in its circuit breaker designs.

6.5

Switches and Fixtures

Inspected
Summary photo 1 6.5-1
COMMENT:

The switch was not responding at the time of inspection; next to the kitchen oven, further evaluation is recommended, replacement likely.

Summary photo 1 6.5-4
COMMENT:

The lightbulb in the utility laundry room was not responding, or Inspector could not locate switch; further evaluation and repair are recommended for proper operation.

6.6

Receptacles (AFCI/GFCI tested)

Inspected
Summary photo 1 6.6-1
COMMENT:

Two-prong outlets were observed in some areas, indicating they are not grounded. This may be a requirement for some loan types, upgrade by qualified electrician as needed. 2-prong outlets can not be fully tested.

Summary photo 1 6.6-3
COMMENT:

GFCI protection was not present, this is a requirement for some loan types.

Summary photo 1 6.6-5
COMMENT:

An open electrical receptacle or exposed wires were observed. Repair by a qualified electrician is recommended.

6.7

Smoke/CO detectors

Deficient
SAFETY ISSUE
Summary photo 1 6.7-1
COMMENT:

Additional smoke and carbon monoxide detectors were noted as needed throughout the property. Proper placement of these devices is crucial for early warning in case of fire or carbon monoxide leaks. Further evaluation by local jurisdiction is recommended.

8. Doors, Windows & Interior - Summary

8.1

Windows and Doors (Representative Number)

Inspected
Summary photo 1 8.1-2
COMMENT:

Unknown repairs by the home owner were noted on the localized window. Evaluation window. Further evaluation is recommended.

8.2

Floors, Walls and Ceilings

Inspected
Summary photo 1 8.2-1
COMMENT:

Stains were observed on the living room ceiling at 3 ft.² or more or at two locations or more. Moisture readings indicated these areas were dry at the time of inspection, suggesting past moisture; monitor for changes. Seller disclosed to inspector these stains have been present since last replacement of the shingles.

Summary photo 1 8.2-6
COMMENT:

The Fan was not responding at the time of inspection. A localized stain was also observed in the nearby area; monitor condition for changes or evaluate. Area dry at time.

Summary photo 1 8.2-7
COMMENT:

Staining was observed on the bedroom ceiling at the time of inspection. Determining the source goes beyond the scope of this inspection; further evaluation is recommended if changes occur. Area was dry at time.

Summary photo 1 8.2-8
COMMENT:

Localized dry staining was observed on the bedroom ceiling at the time of inspection. Monitoring for changes is recommended.

Summary photo 1 8.2-9
COMMENT:

Localized deterioration and peeling paint were observed on the bedroom ceiling. This condition is consistent with normal wear and tear. Monitoring the area for any changes is recommended.

Summary photo 1 8.2-11
COMMENT:

Localized staining was observed on the closet wall. Determining the cause goes beyond the scope of this inspection; further evaluation is recommended if changes occur.

PROFESSIONAL NEEDED
Summary photo 1 8.2-14
COMMENT:

The bathroom wall upstairs appears to bow inward. Determining the cause goes beyond the scope of this inspection; further evaluation is recommended. Not able to determine if related to moisture.

9. Kitchen & Appliances - Summary

9.1

Appliances

Inspected
Summary photo 1 9.1-1
COMMENT:

The gas supply to the oven was off at the time of inspection. Not inspected.

10. Garage - Summary

10.1

Exterior

Inspected
Summary photo 1 10.1-4
COMMENT:

Slightly lifted or curled siding was observed on the detached garage in a localized area.

Summary photo 1 10.1-6
COMMENT:

Siding was observed out of place or exposed on the detached garage; repair is recommended.

11. Bathroom - Summary

11.1

Bathtub & Surrounding

Inspected
Summary photo 1 11.1-1
COMMENT:

The bathroom wall surrounding showed signs of deterioration. Further evaluation and repair by a qualified contractor are recommended. Tape or adhesive was covering these areas. Failure to correct could result in moisture entry or damages.

Summary photo 1 11.1-2
COMMENT:

The bathtub drainage does not keep up with the water source. Further evaluation and repair by a qualified plumber is recommended. Clean drain and recommend a sewer scope to determine the waste pipe condition.

11.2

Shower

Inspected
Summary photo 1 11.2-1
COMMENT:

Maintenance of the showerhead is recommended. Active leak when the water source is turned on.

Report Details
Sewer Scope NO - We Do Not Preform Sewer or Plumbing Camera Scope
Approximate Age 50+ Years old
Attending the Inspection Owner/Family
Type of building Single Family
Occupancy Unoccupied- long term
Animal(s) Present No Dog Present, No Cat Present, Disclosed cat used to live on properry
Weather during the Inspection Clear
Additional Structure Yes - garage
Ground/Soil surface condition Dry
Outdoor Temperature Over 65 (F) = 18 (C)
Water Quality Test No - We do not preform water testing
Radon Test No - At this time we do not preform radon testing
Mold Test No
Thermostat Temperature on Arrival 72
Snow / Rain precipitation in last 3 days No
Thermostat Location Upstairs
Odor Present at Time of Inspection No
Chemical / Meth Residue Testing No - Our Company Does Not Provide This Service
1
Roof
5 Inspected

The roof inspection is limited to visible and readily accessible components at the time of the inspection. The inspection does not determine remaining service life, future performance, or confirm proper installation of roofing materials or components. Concealed conditions, weather conditions, roof pitch, height, or other limitations may restrict the inspection. Defects or conditions not visible at the time of the inspection may exist.

Styles & Materials
Roof Covering Materials *Asphalt Shingle
Drainage SystemGutters and downspouts installed
Viewed Roof FromDrone with camera
Roof Structure Ventilation Device TypeSoffit vents
Active Roof Leak Observed *No active however stains in areas dry at time.
1.1 Roof Covering Materials Inspected
Inspection photo1.1-1
COMMENT:

Shingles appeared to be slightly raised or were not laying flat, similar to nearby shingles. Continued monitoring during routine maintenance is recommended to ensure the long-term integrity of the roofing system. May indicate hidden failure below the roof covering. Keep budget for repairs when shingles are replaced.

Inspection photo1.1-2
COMMENT:

A slightly raised shingle was observed on the roof surface. This condition may allow moisture to penetrate beneath the surface, potentially leading to leaks. Continued monitoring during routine maintenance is recommended to ensure the long-term integrity of the roofing system.

Inspection photo1.1-3
COMMENT:

Moderate granule loss was observed on the roof shingles, which is consistent with an aging roof. Based on an age of 1999, the roof would be at or near its end of life span. The client should confirm the exact age with the seller and budget for eventual replacement.

1.2 Gutters Inspected
Inspection photo1.2-1
COMMENT:

Gutters were observed to require cleaning. Regular maintenance is recommended. Appears to drip or spill in areas.

1.3 Vents, Flashing & Roof Penetrations Inspected
1.3-1
COMMENT:

Replace sealant as needed at roof vents as needed for maintenance.

1.4 General Roof Structure Inspected
2
Exterior
12 Inspected

The exterior inspection is limited to visible and readily accessible components at the time of the inspection. The inspection does not determine future performance, remaining service life, or compliance with current building requirements. Conditions concealed by finishes, vegetation, stored items, or other obstructions may not be visible. Maintenance needs, deterioration, and conditions not visible at the time of the inspection may exist.

Styles & Materials
Wall Covering Material *Lap
Walkway MaterialsConcrete
Driveway MaterialConcrete
Additional StructuresDetached Shed(s) / Garage
Deck AttachmentNo Deck Installed
Improper Spacing Between Balusters And Rails *Stair Railing Opening Too Wide
2.1 Exterior Wall Covering Materials Inspected
Inspection photo2.1-1
COMMENT:

Cracked siding was observed near the front entry door. Repair is recommended for appearance and reduce moisture/insect entry. Front of home.

Inspection photo2.1-2
COMMENT:

Cosmetic wear and tear was observed at the storm door or nearby trim at the rear of the home. Rear of home.

2.2 Eaves, Soffits & Fascia Inspected
2.3 Windows (Exterior) Inspected
Inspection photo2.3-1
COMMENT:

A loose trim or component was observed at the window. It was not possible to determine if it was a storm window or double pain window; further evaluation is recommended. Appears general maintenance.

Inspection photo2.3-2
COMMENT:

General maintenance around windows, such as sealant application, is recommended.

Inspection photo2.3-3
COMMENT:

Plexiglass at the basement window, rear of home, appears to have wear and tear behind its covering.

Inspection photo2.3-4
COMMENT:

Peeling paint was observed on the window and trim at the rear of the home on 2 or more windows. This condition appears cosmetic.

Inspection photo2.3-5
COMMENT:

Wear and tear consistent with age was observed around the windows, and general maintenance is recommended. Replace sealant as needed.

2.4 Exterior Doors Not Inspected
2.5 Flashing & Trim Inspected
2.6 Walkways & Driveways Inspected
2.7 Stairs, Steps, Stoops, Stairways & Ramps Inspected
Inspection photo2.7-1
COMMENT:

Space between railing measured 4 inches or more, which is common in homes of this age. However may be a requirement for some loan types.

Inspection photo2.7-2
COMMENT:

Moderate, however general wear and tear at concrete with exposed rebar, was noted at the front entry stairs. The material was not loose at the time of inspection however appeared to have a crumbling effect. A gap or exposed area was also present. Maintenance to increase life span.

2.8 Vegetation, Surface Drainage, Retaining Walls & Grading Inspected
Inspection photo2.8-1
COMMENT:

Overhanging trees and vegetation were observed at the time of inspection.

Inspection photo2.8-2
Representative photo.
COMMENT:

Visual access to the exterior wall was limited by vegetation; regular maintenance is recommended. Comments on visual ares only. Trimming is needed to see the exterior wall. Limited visibility.

Inspection photo2.8-3
COMMENT:

A window was not visible due to vegetation at the time of inspection. Recommend trimming the vegetation for proper access and maintenance.

3
Structural Components
13 Inspected

The structural inspection is limited to visible and readily accessible components at the time of the inspection. The inspection does not include engineering analysis or determine structural design adequacy. Concealed conditions, defects within inaccessible areas, or conditions not visible at the time of the inspection may exist. Further evaluation by a qualified professional is recommended when concerns are identified.

Styles & Materials
Foundation ConfigurationUnfinished basement
Foundation Type *Concrete Masonry Unit (CMU) foundation walls
Floor StructureWood
3.1 Foundation Inspected
Inspection photo3.1-1
COMMENT:

Shrinkage or settlement cracks were observed, reliant on the ceiling, with a slight amount of displacement. Further evaluation by a qualified structural engineer is recommended.

Inspection photo3.1-2
COMMENT:

Previous cracking was observed to be repaired, appearing cosmetic and consistent with standard practice.

Inspection photo3.1-3
COMMENT:

Areas reliant on foam were noted at the foundation wall at the time of inspection. This condition may compromise the integrity of the foundation. Further evaluation by a qualified professional is recommended.

Inspection photo3.1-4
COMMENT:

A very small amount of missing mortar was observed. Cosmetic maintenance or replacement is recommended as needed.

3.2 Basement Inspected
Inspection photo3.2-1
COMMENT:

A horizontal crack was observed with no major displacement or bowed walls. Monitor this condition over time for any changes.

Inspection photo3.2-2
COMMENT:

The home appeared to have a channel or beaver style basement perimeter water control system. The basement was dry at the time of inspection.

Inspection photo3.2-3
COMMENT:

The basement floor structure is supported by wood and steel jacks, for your information only.

Inspection photo3.2-4
COMMENT:

Stains indicating past moisture were observed on the basement framing. The area was dry at the time of inspection; monitor for changes. Not able to determine past or future changes.

Inspection photo3.2-5
COMMENT:

Flooring has been removed in the unfinished basement.

3.3 Floor Structure Inspected
PROFESSIONAL NEEDED
Inspection photo3.3-1
COMMENT:

The floor in the upstairs bathroom near the toilet was observed to be not level. Localized staining was noted on the vinyl; further evaluation is recommended. The nearby wall was bowed out. Further evaluation in this area is strongly recommended. The nearby vinyl near toilet had a stain. Dry at time.

Inspection photo3.3-2
COMMENT:

Stains were observed on the floor structure. Determining the cause goes beyond the scope of this inspection; monitor for changes. Not able to determine past or intermittent conditions.

Inspection photo3.3-3
COMMENT:

Stains were observed on the floor structure above the upstairs bathroom. This area was dry at the time of inspection; monitor for changes.

Inspection photo3.3-4
COMMENT:

Stains were observed on the floor structure. The area was dry, and monitoring is recommended. Representative photo.

4
Heating & Cooling
9 Inspected

The heating system inspection is limited to visible and accessible components and basic operational testing at the time of the inspection. The inspection does not determine efficiency, remaining service life, or compliance with manufacturer specifications. Internal components and conditions not visible or accessible during the inspection may not be evaluated.

Styles & Materials
Furnace Energy Source *Gas
Heating Method *Heat Pump Forced Air (also provides cool air)
Heating System BrandCarrier
Furnace FilterDisposable
Heating/Cooling DuctsPossible asbestos sleeving
Cooling System TypeAir Conditioner Unit
Cooling Equipment Energy Source *Electricity
Cooling System ManufacturerRheem
Heating System Inaccessible *No
Location Of The Thermostat *Upper level
Cooling System Inaccessible *No
4.1 Heating System Inspected
WARNING
Inspection photo4.1-1
COMMENT:

Potential asbestos wrap was observed on the heating system. Testing or appropriate covering is recommended.

Inspection photo4.1-2
COMMENT:

The serial number for the furnace was noted at the time of inspection.

Inspection photo4.1-3
COMMENT:

The furnace appeared to be responding under normal operation at the time of inspection.

4.2 Cooling System Inspected
Inspection photo4.2-1
COMMENT:

The serial number for the air conditioner was recorded. It was responding at time of inspection. Using thermostat.

Inspection photo4.2-2
COMMENT:

Aged insulation was observed on the air conditioner entry line. Consider obtaining a cost estimate for repair.

Inspection photo4.2-3
COMMENT:

Vegetation around the air conditioner unit should be trimmed. No major debris was observed on the exterior fins; however, monitor this condition.

4.3 Thermostat Inspected
4.3-1
COMMENT:

Non programmable for you information only.

4.4 Fuel, Piping & Support Inspected
Inspection photo4.4-1
COMMENT:

Duct work was localized crushed or damaged and is for your information; this is a cosmetic condition or may reduce air flow slightly in this area.

Inspection photo4.4-2
COMMENT:

The fuel supply was observed shut off in the basement at the time of inspection.

5
Plumbing
14 Inspected

The plumbing inspection is limited to visible and readily accessible components at the time of the inspection. The inspection does not determine the remaining service life, capacity, or future performance of plumbing systems. Concealed piping, underground components, and conditions not visible during the inspection may exist.

Styles & Materials
Main Water Supply MaterialsPoly
Sewage System TypePublic
Drain Waste and Vent Pipe MaterialsPolyvinyl Chloride (PVC), Metal, Copper
Water Heater Fuel Type *Gas
Sump PumpNone
Type of GasNatural Gas
Water Treatment Systems/FiltersNone
Dryer Gas SupplyNatural gas
Main Fuel Supply Pipe (shut off) *At Meter
Fuel storage location (if present) *None
5.1 Main Water Supply Shut-Off Valve Inspected
Inspection photo5.1-1
COMMENT:

At the time of inspection, the main water supply pipe, identified as poly. This area showed signs of corrosion. This condition was dry at the time of inspection; Monitor for changes, appears to be from past repair.

5.2 Main Fuel Supply Shut-Off Valve Inspected
Inspection photo5.2-1
COMMENT:

The main gas line was inspected in visual areas only. Exterior location. The main shut off located at basement.

5.3 Water Heater - Venting, TPR Valves & Seismic Bracing Inspected
SAFETY ISSUE
Inspection photo5.3-1
COMMENT:

It is recommended to reduce the water temperature to 120 Fahrenheit. 138 degrees at time, may increase chance of burns.

Inspection photo5.3-2
COMMENT:

The water heater serial number was noted. Manufactures date 2019

5.4 Interior Water Supply, Fixtures & Faucets Inspected
Inspection photo5.4-1
COMMENT:

The water source to the exterior spigot was off at the time of inspection, preventing full evaluation of its condition and operation. This condition limits the ability to determine if leaks or other issues are present. Further evaluation is recommended once the water supply is active.

Inspection photo5.4-2
COMMENT:

A leak was observed at the water spigot when the water source was turned on. Further evaluation and repair by a qualified plumber are recommended.

Inspection photo5.4-3
COMMENT:

Corrosion was observed on a plumbing pipe. This condition appeared old or cosmetic, and monitoring is recommended.

5.5 Toilets (Operable by flushing) * Inspected
5.6 Sinks, Tubs & Showers (Functional Drainage) Inspected
Inspection photo5.6-1
COMMENT:

No shut-off valves were observed for the sink at the time of inspection. Without these valves, it is not possible to isolate water flow to the fixture for maintenance or in case of a leak. Recommend installation of shut-off valves by a qualified plumber.

Inspection photo5.6-2
COMMENT:

The sink drain in the upstairs bathroom was observed to be slightly slow. Monitor this condition over time. Strongly recommend a sewer scope.

5.7 Drain, Waste & Vent System Not Inspected
Inspection photo5.7-1
COMMENT:

The cover for what appeared to be the sewer clean-out cover was deteriorated. Replacement is recommended. Recommend replacement of a new cap.

Inspection photo5.7-2
COMMENT:

An open or exposed drain pipe should be sealed, at washing machine. Visible corrosion or scaling was noted on the base of the washing machine; keep budget in mind for replacement.

Inspection photo5.7-3
COMMENT:

No floor drain was observed in the basement at the time of inspection. Without a proper floor drain, water accumulation from leaks or spills could lead to moisture issues and potential damage. Consider obtaining a cost estimate for installation to ensure proper conditions exist. Increase chance of trip and fall.

Inspection photo5.7-4
COMMENT:

The main waste pipe was observed. Blockages or damage within the main waste pipe can lead to significant plumbing issues and potential backups. A sewer scope inspection is recommended to assess the internal condition of the pipe.

5.8 Functional Drainage Inspected
5.9 Sump Pumps w/ Accessible Floats Not Inspected
5.9-1
COMMENT:

None, not present.

6
Electrical
16 Inspected 2 Deficient

The electrical inspection is limited to visible and readily accessible components at the time of the inspection. The inspection does not include a complete electrical engineering evaluation or verify compliance with all current codes and standards. Concealed wiring, internal components, and conditions not visible during the inspection may exist.

Styles & Materials
Service Entrance Conductor Type *Underground service
Ground Fault Circuit Interruptor (GFCI) ProtectionNo
Arc Fault Circuit Interruptor (AFCI) ProtectionNo
Service Size (Amperage) *Recommend further evaluation
Service Panel ManufacturerFederal Pacific
Grounding MethodFuses
Type of Wiring *Cloth-coated, Romex
Service entrance wire condition (insulation, drip loop, clearances)Satisfactory at time of inspection
Unused Circuit-Breaker Panel Opening That Was Not Filled *Satisfactory at time of inspection
Absence of Smoke and/or Carbon Monoxide Detectors *Smoke detectors missing, CO detectors missing
6.1 Meter and Service Wiring Inspected
Inspection photo6.1-1
COMMENT:

A hanging or loose wire was observed, and further evaluation and repair by a qualified electrician is recommended.

Inspection photo6.1-2
COMMENT:

Aged Romex wiring was observed in the home. This type of wiring may not meet current electrical codes and can pose a safety hazard. Further evaluation by a qualified electrician as needed.

6.2 Main Panel and Breakers Deficient
DANGERPROFESSIONAL NEEDED
Inspection photo6.2-1
COMMENT:

A Federal Noark electrical panel is an older distribution box made by the company that later became Federal Pacific Electric (FPE), and it poses significant safety and fire risks due to known failure-to-trip defects in its circuit breaker designs.

6.3 Switches and Fixtures Inspected
Inspection photo6.3-1
COMMENT:

The switch was not responding at the time of inspection; next to the kitchen oven, further evaluation is recommended, replacement likely.

Inspection photo6.3-2
COMMENT:

A cracked face plate with tape was observed on the switch in the upstairs master bedroom. Replace as needed.

Inspection photo6.3-3
COMMENT:

A hanging or loose switch was observed. Re-secure by a qualified electrician is recommended.

Inspection photo6.3-4
COMMENT:

The lightbulb in the utility laundry room was not responding, or Inspector could not locate switch; further evaluation and repair are recommended for proper operation.

6.4 Receptacles (AFCI/GFCI tested) Inspected
Inspection photo6.4-1
COMMENT:

Two-prong outlets were observed in some areas, indicating they are not grounded. This may be a requirement for some loan types, upgrade by qualified electrician as needed. 2-prong outlets can not be fully tested.

Inspection photo6.4-2
COMMENT:

A cracked 2-prong receptacle was observed and could not be fully tested. Repair by a qualified electrician is recommended.

Inspection photo6.4-3
COMMENT:

GFCI protection was not present, this is a requirement for some loan types.

Inspection photo6.4-4
Representative photo
COMMENT:

Missing face plates were observed in three or more areas. This condition exposes electrical components, which can pose a safety hazard. Repair by a qualified electrician is recommended. Some 3 prong outlets were ungrounded.

Inspection photo6.4-5
COMMENT:

An open electrical receptacle or exposed wires were observed. Repair by a qualified electrician is recommended.

Inspection photo6.4-6
COMMENT:

The use of extension cords for personal items was observed. Appears to be related to personal items or extension block, evaluation is recommended.

6.5 Smoke/CO detectors Deficient
SAFETY ISSUE
Inspection photo6.5-1
COMMENT:

Additional smoke and carbon monoxide detectors were noted as needed throughout the property. Proper placement of these devices is crucial for early warning in case of fire or carbon monoxide leaks. Further evaluation by local jurisdiction is recommended.

6.6 Low Voltage Not Inspected
Inspection photo6.6-1
COMMENT:

Cosmetic damages were observed on low voltage components, such as the doorbell, at both locations. The evaluation of these components goes beyond the scope of this inspection.

7
Attic, Insulation & Ventilation
5 Inspected

The attic inspection is limited to visible and accessible areas at the time of the inspection. Insulation, stored items, limited access, and other conditions may restrict visibility of components. The inspection does not determine future performance of ventilation, insulation, or roofing components. Conditions concealed from view may exist.

Styles & Materials
Attic inspected fromAt Entry
Attic Insulation Material *Batt, Blown-in
Venting TypeAppears to vent to exterior of home
Type of Insulation *Fiberglass Batt
7.1 Insulation in Unfinished Spaces (including attics, crawl spaces and foundation areas) * Inspected
Inspection photo7.1-1
COMMENT:

Wiring was observed above the access cover. Caution when opening attic hatch.

Inspection photo7.1-2
COMMENT:

Representative photo of the attic. Discoloration should be closely monitored. See photo gallery for more information.

Inspection photo7.1-3
COMMENT:

Representative photo of the attic.

Inspection photo7.1-4
COMMENT:

Visual access to some areas of the attic was limited due to the size of the access hatch. Further evaluation is recommended once full access is available.

Inspection photo7.1-5
COMMENT:

Localized staining was observed near an exhaust monitor at the time of inspection, which appeared dry. Although common in attics, monitor long term.

Inspection photo 1 7.1-6
Inspection photo 2
COMMENT:
8
Doors, Windows & Interior
23 Inspected

The interior inspection is limited to visible and readily accessible components at the time of the inspection. Cosmetic conditions, normal wear, and defects hidden by furnishings, personal belongings, finishes, or other obstructions may not be identified. The inspection does not determine future performance or remaining service life of interior components.

Styles & Materials
Garage Door Type *Two Automatic
8.1 Windows and Doors (Representative Number) Inspected
Inspection photo8.1-1
COMMENT:

Weather stripping was observed at the time of inspection. For your information, general maintenance.

Inspection photo8.1-2
COMMENT:

Unknown repairs by the home owner were noted on the localized window. Evaluation window. Further evaluation is recommended.

Inspection photo8.1-3
COMMENT:

Cosmetic door damage was observed in the upstairs bathroom. A visible hole over 2" in diameter.

Inspection photo8.1-4
COMMENT:

Cosmetic conditions were observed on the door, leading to the basement. Deterioration.

8.2 Floors, Walls and Ceilings Inspected
Inspection photo8.2-1
COMMENT:

Stains were observed on the living room ceiling at 3 ft.² or more or at two locations or more. Moisture readings indicated these areas were dry at the time of inspection, suggesting past moisture; monitor for changes. Seller disclosed to inspector these stains have been present since last replacement of the shingles.

Inspection photo8.2-2
COMMENT:

Representative photo of the living room, dry at time. 3 or more stains 2sq ft or more.

Inspection photo8.2-3
COMMENT:

Dark discoloration was observed. Lab testing would be needed to determine the nature of this condition. These areas were dry at time.

Inspection photo8.2-4
COMMENT:

Stains were observed on the living room floor where carpet had been removed. These areas were dry at the time of inspection. Stains in several areas where the carpet was removed.

Inspection photo8.2-5
COMMENT:

An active stain was observed on the living room floor. Further evaluation is recommended to determine the source and repair as needed. Inspected asked owner/family if a spill occurred, they did not indicate a source.

Inspection photo8.2-6
COMMENT:

The Fan was not responding at the time of inspection. A localized stain was also observed in the nearby area; monitor condition for changes or evaluate. Area dry at time.

Inspection photo8.2-7
COMMENT:

Staining was observed on the bedroom ceiling at the time of inspection. Determining the source goes beyond the scope of this inspection; further evaluation is recommended if changes occur. Area was dry at time.

Inspection photo8.2-8
COMMENT:

Localized dry staining was observed on the bedroom ceiling at the time of inspection. Monitoring for changes is recommended.

Inspection photo8.2-9
COMMENT:

Localized deterioration and peeling paint were observed on the bedroom ceiling. This condition is consistent with normal wear and tear. Monitoring the area for any changes is recommended.

Inspection photo8.2-10
COMMENT:

Thermal tracking was observed at the time of inspection. Determining the cause goes beyond the scope of this inspection; further evaluation is recommended. Dark color stains were fasteners (nails) were present.

Inspection photo8.2-11
COMMENT:

Localized staining was observed on the closet wall. Determining the cause goes beyond the scope of this inspection; further evaluation is recommended if changes occur.

Inspection photo8.2-12
COMMENT:

Patches and repairs were observed in various areas. Cosmetic only.

Inspection photo8.2-13
COMMENT:

Peeling paint was observed on the upstairs bathroom ceiling. Consider obtaining a cost estimate for repair. No bathroom vent was present upstairs.

PROFESSIONAL NEEDED
Inspection photo8.2-14
COMMENT:

The bathroom wall upstairs appears to bow inward. Determining the cause goes beyond the scope of this inspection; further evaluation is recommended. Not able to determine if related to moisture.

Inspection photo8.2-15
COMMENT:

Deterioration was observed on the upstairs Bathroom floor. Further evaluation by a qualified contractor is recommended.

Inspection photo8.2-16
COMMENT:

Cosmetic settlement cracks were observed on the Master bedroom ceiling upstairs, and it is recommended to monitor this condition over time. Not able to determine past or future changes.

Inspection photo8.2-17
COMMENT:

Carpet was removed in the hallway and living room, revealing stains on the sub-floor. These stains were dry at the time of inspection; monitor for any changes.

Inspection photo8.2-18
COMMENT:

Wear and tear was observed on trim. The seller indicates this condition is from a dog.

8.3 Stairs, Steps, Landings, Stairways & Ramps Not Inspected
8.4 Cabinets Inspected
Inspection photo8.4-1
COMMENT:

Missing drawers were observed at the time of inspection. This is for your information, you may wish to ask seller about this finding.

9
Kitchen & Appliances
5 Inspected

The kitchen and appliance inspection is limited to visible components and basic operational testing at the time of the inspection. The inspection does not verify appliance efficiency, remaining service life, or internal mechanical conditions. Conditions not visible or accessible during testing may exist.

9.1 Appliances Inspected
Inspection photo9.1-1
COMMENT:

The gas supply to the oven was off at the time of inspection. Not inspected.

Inspection photo9.1-2
COMMENT:

Full inspection of the washer and dryer goes beyond the scope of this inspection. The washing machine was aged and showed signs of corrosion; further evaluation is recommended.

9.2 Serial Numbers Inspected
Inspection photo9.2-1
COMMENT:

The oven serial number was recorded.

Inspection photo9.2-2
COMMENT:

The serial number on the washing machine was difficult to read at the time of inspection. Keep a budget in mind for replacement of washer and dryer. Visible corrosion was observed.

Inspection photo9.2-3
COMMENT:

The serial number for the dryer was noted.

10
Garage
13 Inspected
10.1 Exterior Inspected
Inspection photo10.1-1
COMMENT:

Partial gutters were observed on the detached structure.

Inspection photo10.1-2
COMMENT:

Vegetation limited the view of the detached structure's foundation at the time of inspection. Clearing the vegetation is recommended for a complete assessment. Limited inspection.

Inspection photo10.1-3
COMMENT:

Removal of the detached bee or wasp nest in the garage is recommended. Maintenance.

Inspection photo10.1-4
COMMENT:

Slightly lifted or curled siding was observed on the detached garage in a localized area.

Inspection photo10.1-5
COMMENT:

Overhanging trees were observed near the detached structure.

Inspection photo10.1-6
COMMENT:

Siding was observed out of place or exposed on the detached garage; repair is recommended.

Inspection photo10.1-7
COMMENT:

A small amount of settlement was observed in the driveway near the detached structure. General settlement.

10.2 Doors Inspected
Inspection photo10.2-1
COMMENT:

A very small amount of deterioration was observed on the detached garage door.

Inspection photo10.2-2
COMMENT:

A slight amount of fog was observed at the siding glass at the detached garage. This condition appears consistent with general cleaning, and the cause could not be determined.

10.3 Interior Inspected
Inspection photo10.3-1
COMMENT:

The inspection of this area was limited due to personal belongings.

Inspection photo10.3-2
COMMENT:

A dry, cosmetic stain was observed on the garage floor.

10.4 Roof Not Inspected
Inspection photo10.4-1
COMMENT:

Representative photo of garage roof shingles. Owner indicated to inspector that roof was from 1999, you may wish to confirm this finding. No missing tabs, granule loss commensurate with age.

Inspection photo10.4-2
COMMENT:

Representative photo commensurate with age.

11
Bathroom
4 Inspected
11.1 Bathtub & Surrounding Inspected
Inspection photo11.1-1
COMMENT:

The bathroom wall surrounding showed signs of deterioration. Further evaluation and repair by a qualified contractor are recommended. Tape or adhesive was covering these areas. Failure to correct could result in moisture entry or damages.

Inspection photo11.1-2
COMMENT:

The bathtub drainage does not keep up with the water source. Further evaluation and repair by a qualified plumber is recommended. Clean drain and recommend a sewer scope to determine the waste pipe condition.

Inspection photo11.1-3
COMMENT:

Deteriorating conditions were observed on the bathroom wall. Further evaluation is recommended.

11.2 Shower Inspected
Inspection photo11.2-1
COMMENT:

Maintenance of the showerhead is recommended. Active leak when the water source is turned on.